[1]陈纪纲,许晓蓉,林国松,等.高速铁路牵引网双边供电方式下的故障测距策略研究[J].高速铁路技术,2021,12(05):41-45.[doi:10.12098/j.issn.1674-8247.2021.05.008]
 CHEN Jigang,XU Xiaorong,LIN Guosong,et al.Study on Fault Location Strategy for Traction Electric Network of High-speed Railway in Double-end Feeding Mode[J].HIGH SPEED RAILWAY TECHNOLOGY,2021,12(05):41-45.[doi:10.12098/j.issn.1674-8247.2021.05.008]
点击复制

高速铁路牵引网双边供电方式下的故障测距策略研究()
分享到:

《高速铁路技术》[ISSN:1674-8247/CN:51-1730/U]

卷:
12卷
期数:
2021年05期
页码:
41-45
栏目:
出版日期:
2021-10-28

文章信息/Info

Title:
Study on Fault Location Strategy for Traction Electric Network of High-speed Railway in Double-end Feeding Mode
文章编号:
1674—8247(2021)05—0041-05
作者:
陈纪纲 许晓蓉 林国松 林宗良 李原
1. 中铁二院工程集团有限责任公司, 成都 610031;
2. 西南交通大学, 成都 610031
Author(s):
CHEN Jigang XU Xiaorong LIN Guosong LIN Zongliang LI Yuan
1. China Railway Eryuan Engineering Group Co., Ltd., Chengdu 610031, China;
2. Southwest Jiaotong University, Chengdu 610031, China
关键词:
牵引供电系统|AT供电方式|双边供电|故障测距
Keywords:
traction power supply system|AT power supply mode|double-end feeding|fault location
分类号:
U226
DOI:
10.12098/j.issn.1674-8247.2021.05.008
文献标志码:
A
摘要:
随着我国高速铁路牵引供电系统的快速发展,为更好地提高牵引网的供电能力,双边供电方式的牵引网成为选择。本文分析了高速铁路双边全并联AT供电方式下的电路模型,探讨了AT吸上电流比、横联线电流比、上下行电流比与距离的关系特性,分析了传统AT牵引网故障测距原理在双边供电方式下的适应性,提出了采用双端变电所测距装置协同的测距策略,并基于Matlab/Simulink仿真验证了故障测距策略的合理性。
Abstract:
With the rapid development of the traction power supply system of high-speed railway in China, in order to better improve the power supply capacity of the traction network, traction network with double-end feeding mode has become the choice. In this paper, the circuit model of double-end full parallel AT power supply mode for the high-speed railway is analyzed, and the relationship between AT’s current ratio, cross-line current ratio, up-down current ratio, and distance is discussed. The adaptability of the traditional AT traction network fault location principle in bilateral power supply mode is analyzed, and a fault location strategy with the cooperation of two-terminal substation fault location devices is proposed. The rationality of the fault location strategy is verified based on Matlab/Simulink simulation.

备注/Memo

备注/Memo:
作者简介:陈纪纲(1977-),男,教授级高级工程师。基金项目:中铁二院工程集团有限责任公司科技开发计划(KSNQ202056)引文格式:陈纪纲, 许晓蓉, 林国松, 等. 高速铁路牵引网双边供电方式下的故障测距策略研究[J]. 高速铁路技术,2021,12(5):41-45.CHEN Jigang, XU Xiaorong, LIN Guosong, et al. Study on Fault Location Strategy for Traction Electric Network of High-speed Railway in Double-end Feeding Mode[J]. High Speed Railway Technology, 2021, 12(5):41-45.